Miillar Instruments HomeDistributor ContactSite Map
Miillar Instruments
Research Clinical Published Papers Sales About Millar Registered User Policies


Products

Research
---------------------
Pressure Volume Systems
---------------------
Multi-Segment P-V
---------------------
Ultra-Miniature P-V
---------------------
Mikro-Tip® Pressure
---------------------
Ultra-Miniature Pressure
---------------------
Implantable Mikro-Tip® Pressure
---------------------
Telemetry

-------------------
Electrophysiology
---------------------
Pressure Control Units
---------------------
PowerLab® Data Acquisition
---------------------
MPress Software
---------------------
PVAN Software
---------------------
Specialty Catheter Services

Clinical
----------------------
Mikro-Tip® Pressure
----------------------
Multi-Segment Pressure Volume
----------------------
Angiographic
----------------------
Urology
----------------------
Pressure Control Units
----------------------
Specialty Catheter Services

 
  Research: Pressure-Volume Systems: MPVS Ultra : PVAN Ultra

PVAN Ultra™ Data Analysis Software

Millar's PVAN Ultra software provides a powerful, easy-to-use method for investigators to calculate the hemodynamic parameters of the P-V data generated by the Millar Pressure Volume Systems.

Parameters calculated by PVAN Ultra

PVAN Ultra opens the text files generated by the data acquisition software and applies a variety of algorithms to the P-V data to calculate over thirty different hemodynamic parameters.

Parameters Calculated by PVAN Ultra Software
HR Heart Rate Ea Arterial Elastance dP/dt min Minimum dP/dt
Vmax Maximum Volume CO Cardiac Output dV/dt max Maximum dV/dt
Vmin Minimum Volume SW Stroke Work dV/dt min Minimum dV/dt
Ves End-Systolic Volume SV Stroke Volume P@dP/dt max Pressure at dP/dt Max
Ved End-Diastolic Volume EF Ejection Fraction P@dV/dt max Pressure at dV/dt Max
Pmax Maximum Pressure PRSW Preload Recruitable SW V@dP/dt max Volume at dP/dt Max
Pmin Minimum Pressure ESPVR End-Systolic P-V Relationship V@dP/dt min Volume at dP/dt Min
Pes End-Systolic Pressure EDPVR End-Diastolic P-V Relationship Tau (Weiss) Tau-Weiss Method
Ped End-Diastolic Pressure E(t) Time Varying Max. Elastance Tau (Glantz) Tau-Glantz Method
Ees End-Systolic Elastance dP/dt max Maximum dP/dt Tau (Logistic) Tau-Logistic Method

The calculated hemodynamic parameters serve as indicators of cardiovascular performance in response to different interventions (genetic mutations, drugs, occlusions, etc.). PVAN Ultra offers the investigator the opportunity to convert data to units of true volume if the data are recorded RVUs (Relative Volume Units) or conductance units.

PVAN Ultra Data Analysis Software

PVAN Ultra contains an intuitive user menu that offers easy access to a variety of displays and calculation tables for several cardiovascular parameters. A saline calibration feature allows the user to obtain a value for the parallel conductance volume contribution of the myocardium.

PVAN Ultra

 

 

Data Export

Data may be easily exported to spreadsheets or text files, and graphical information can be placed into presentations or papers for publication.



 

  Millar Instruments, Inc. | 6001-A Gulf Freeway Houston, Texas 77023-5417 USA | 832.667.7000