  Research: Pressure-Volume Systems: Ultra-Miniature Pressure-Volume Catheters

Ultra-Miniature Pressure-Volume Catheters
Animal Use Only

The World's Smallest Sensor Tip Pressure-Volume Catheter: PVR-1045

With a catheter tip size of 1F (1/3mm), the PVR-1045 is the newest addition to Millar's market-leading line of ultra-miniature catheters for use in small animal research. The smaller diameter gives researchers a powerful new tool in the characterization of cardiovascular function by allowing access to smaller animals than ever before possible.

Millar’s Mikro-Tip® ultra-miniature P-V catheters have revolutionized the possibilities for cardiovascular research in small animals. These ultra-miniature catheters are capable of measuring both left ventricular pressure and volume simultaneously from the intact, beating hearts of mice and rats. They may be used in either closed-chest or open-chest surgical procedures, as well as in isolated working heart studies.

P-V Catheter Features

  • Ultra-miniature 1F-2F (0.33-0.67 mm outer diameter) pressure sensors
  • Four electrodes (spaced for either mice or rats)
  • Pressure and volume measurement from a single instrument
  • Flexible, durable, small-diameter catheter material
  • High frequency response
  • Pressure measurement at the source
  • No motion artifact or damping of pressure signal
  • For use with Millar Pressure Volume Systems, MPVS 300/400 and MPVS Ultra
PVR-1045

Ultra-Miniature P-V Catheter Models

Features/Model PVR-1045 PVR-1035 SPR-839 SPR-869 SPR-838
Part Number 842-0001 842-0002 840-8111 840-8136 840-8110
Animal Type Mouse Mouse Mouse Small rat Normal/large rat
Catheter Material Polyimide Polyimide Polyimide Polyimide Polyimide
Effective Length 3.25 cm 3.25 cm 3.5 cm 12.5 cm 12.5 cm
French Size (Sensor) 1 1 1.4 2 2
French Size (Catheter Body) 0.8 0.8 0.8 1.1 1.1
Number of Pressure Sensors 1 1 1 1 1
Sensor Location from Tip Centered in
electrode segment
Centered in
electrode segment
Centered in
electrode segment
Centered in
electrode segment
Centered in
electrode segment
Electrodes (0.25 mm) 4 4 4 4 4
Pin-to-Electrode Resistance < 15 ohms < 15 ohms < 15 ohms < 15 ohms < 15 ohms
Electrode Spacing 4.5 mm segment 3.5 mm segment 4.5 mm segment 6.0 mm segment 9.0 mm segment
Electrode Connector Redel Redel Redel Redel Redel
Pressure Sensor Connector Low profile Low profile Low profile Low profile Low profile
Reusable Yes Yes Yes Yes Yes
Repairable No No Yes Yes Yes

 

 